The article proves the relevance of extending the life of power transformers of traction substations of alternating current of electric railways. The service life of the transformers of many substations on the Far East Railway exceeds the standard service life. Replacing existing transformers with new ones will require huge investments. Every fourth case of transformer failure is associated with damage to the winding insulation. According to the results of the analysis of the operation of transformers, it was proved that the wear of winding insulation is uneven. To assess the wear of winding insulation of existing transformers, a method has been developed that allows determining the residual insulation resource. To reduce the wear rate of winding insulation, which limits the life of existing transformers, new connection schemes are proposed. Extending the life of the winding with the greatest insulation wear increases the life of the transformers. Determination of the predicted life of the corresponding transformer by thermal wear of winding insulation ensures their monitoring in operation. The determination of the relative wear of winding insulation in retrospect is based on the analysis of the executed train schedules. For each substation, a transformer connection diagram is determined, which ensures a decrease in the wear rate of winding insulation, which limits the life of the transformer in the future. The work proves the technical and economic efficiency of extending the life of transformers of traction substations of alternating current of electric railways.
机译:本文证明了延长电气交流电流牵引变电站电力变压器寿命的相关性。远东铁路许多变电站的变压器的使用寿命超过了标准的使用寿命。用新的更换现有的变形金刚需要巨额投资。每次第四种变压器故障都与绕组绝缘损坏有关。根据变压器操作分析的结果,证明绕线绝缘的磨损是不均匀的。为了评估现有变压器的绕组绝缘的磨损,已经开发了一种方法,允许确定残余绝缘资源。为了降低绕组绝缘的磨损率,这限制了现有变压器的寿命,提出了新的连接方案。延长绕组的寿命,最大的绝缘磨损会增加变压器的寿命。通过绕组绝缘的热磨确定相应变压器的预测寿命确保其在操作中的监测。回顾中绕组绝缘的相对磨损的确定是基于对执行的列表时间表的分析。对于每个变电站,确定变压器连接图,其确保绕组绝缘的磨损率降低,这限制了未来变压器的寿命。该工作证明了延长了电气交流电流牵引变电站变电站寿命的技术和经济效率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号