The present work illustrates the scheme that aims the design and analysis of high-frequency induction heating equipment using boost PFC converter with reduced total harmonic distortion. The boost PFC tries to reduce harmonics in the input side by turning on and off the MOSFET with varying duty cycle. It can efficiently reduce the THD, taking the power factor to nearly unity. The THD in the input current waveform of the IHE with the installation of the boost PFC was found to be 3.445% and was free from distortions. However, the IHE without boost PFC circuit has THD 47.48% which gives very poor power factor quality. Thus, the boost PFC converter improves the power factor and efficiency of an IHE.
机译:本工作说明了旨在使用升压PFC转换器的高频感应加热设备的设计和分析,总谐波失真减少。 升压PFC试图通过具有不同占空比的MOSFET开启和关闭MOSFET来减少输入侧的谐波。 它可以有效地减少THD,将功率因数取向近乎统一。 IHE的输入电流波形的THD发现升压PFC的安装为3.445%,没有扭曲。 但是,没有升压PFC电路的IHE具有47.48%,其功率因数质量很差。 因此,升压PFC转换器提高了IHE的功率因数和效率。