The Denver Dept. of Public Health and Environment (DDPHE) has deployed and evaluated numerous low cost sensors that measure PM2.5, temperature, and relative humidity since early 2018. We have sensors collocated in triplicate at Interstate 25 Globeville(I25GLO; a USEPA near road site in an environmental justice area), one at La Casa (a USEPA NCoresite), and one at National Jewish Hospital (a PM2.5 FEM site). Low cost sensors are garnering significant interest from regulatory agencies, researchers, and community groups as a way to measure relative differences in space and time, especially for unique events like wildfires and other source specific hot spots. Denver is focusing on PM2.5 to start based on good comparisons to FRM and FEM instruments in other real world field studies. The USEPA sites at GLO and LaCasause GRIMM 180 EDM instruments to measure PM2.5, while at National Jewish Hospital a Teledyne 640 is utilized. We will present results showing sensor to sensor variability, comparison with two federal equivalent method (FEM) instruments, and comparing sensors to FEM instruments with different aerosol characteristics, i.e. near road vs residential. We will show overall bias of the sensors against the FEM instruments, seasonal variation based on temperature and humidity changes, and how we are reporting data to the community, both corrected and uncorrected. Denver will also discuss our expanding sensor network over the next several years as a result of a $1M Bloomberg Mayor's Challenge grant and how we are partnering with the local school district to make this exposure information actionable for the 10%+ of Denver Public School students affected by asthma. We also have plans to strategically deploy at least 100 more sensors throughout the city via an innovative public private partnership (P3), that will add nitrogen dioxide and/or ozone to the monitoring suite.
机译:丹佛公共卫生和环境部(DDPHE)部署并评估了许多测量PM2的低成本传感器。5.2018年初以来的温度和相对湿度。我们在25号州际公路Globeville(I25GLO;环境正义区内靠近公路的美国环保局现场)配置了三个传感器,一个在La Casa(美国环保局NCoresite),一个在国家犹太医院(PM2.5 FEM现场)。作为一种测量空间和时间相对差异的方法,低成本传感器正引起监管机构、研究人员和社区团体的极大兴趣,尤其是对于野火和其他特定源头热点等独特事件。丹佛的重点是PM2。5.在与其他实际现场研究中的FRM和FEM仪器进行良好比较的基础上开始。美国环保局在GLO和Lacasa的站点使用GRIMM 180 EDM仪器测量PM2。5.在国立犹太医院使用Teledyne 640。我们将展示显示传感器之间可变性的结果,与两种联邦等效方法(FEM)仪器进行比较,并将传感器与具有不同气溶胶特性的FEM仪器进行比较,即近道路与住宅。我们将展示传感器相对于FEM仪器的总体偏差,基于温度和湿度变化的季节变化,以及我们如何向社区报告数据,包括纠正和未纠正的数据。丹佛还将讨论,由于彭博市长100万美元的挑战补助金,我们将在未来几年扩大传感器网络,以及我们如何与当地学区合作,使10%以上的丹佛公立学校受哮喘影响的学生可以使用这些暴露信息。我们还计划通过创新的公私合作伙伴关系(P3),在全市范围内战略性地部署至少100多个传感器,将二氧化氮和/或臭氧添加到监测套件中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号