首页> 外文会议>International Conference on Construction, Architecture and Technosphere Safety >α-factor experimental determination of aeration system in aeration tanks
【24h】

α-factor experimental determination of aeration system in aeration tanks

机译:α-因子曝气池曝气系统的实验测定

获取原文

摘要

The article is dedicated to determine the a-factor of aeration systems in case of changing the wastewater treatment line(transfer of aeration tanks to the nitri-denitrifier aeration mode).The studies were performed on an experimental installation with sewage and activated sludge at one of the sewage treatment facilities of the Udmurt Republic.During the process of determining the parameter under consideration,pure water and the sludge mixture from the experimental plant were sequentially aerated at the same conditions;thus,the K_Lα was sequentially determined for two different types of liquids.The ratio of different liquids defined under the same conditions of K_Lα determines the a-factor.Plate aerators with a dispersing element made of a rubber membrane were used as an experimental plants,thanks to which a high calculated value of the a-factor was found - 0.95 ± 0.03.
机译:该物品专用于确定避免废水处理线(通气罐转移到Nitri-Decitrizer曝气模式)的情况下确定曝气系统的A型因素。在一个实验装置中进行了一个污水和活化污泥的研究 在UDMURT共和国的污水处理设施中。在相同条件下依次曝光,确定所考虑的参数,纯水和实验植物的污泥混合物的过程;因此,依次确定k_1α以两种不同类型的 液体。在相同条件下定义的不同液体的比例决定了A型因子。使用由橡胶膜制成的分散元件作为实验植物,归因于该辅助植物的辅助植物 发现 - 0.95±0.03。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号