首页> 外文会议>Image-Guided Procedures, Robotic Interventions, and Modeling >Dual-modality phantom for evaluating x-ray/echo registration accuracy
【24h】

Dual-modality phantom for evaluating x-ray/echo registration accuracy

机译:用于评估X射线/回声登记精度的双式模型幻像

获取原文
获取外文期刊封面目录资料

摘要

Transcatheter interventions for structural heart disease demand real-time visualization of catheter devices and their relationship to cardiac anatomy. Co-registration of x-ray fluoroscopy with echocardiography has been proposed to provide the necessary device and soft tissue visualization for these procedures. Development of real-time 3D x-ray/echo registration systems with device tracking has been hampered by the lack of a suitable test model. This study presents a phantom that is compatible with x-ray, CT, transthoracic (TTE), and transesophageal echo (TEE) for testing the feasibility and accuracy of new registration solutions. The phantom consists of a 20.3-cm diameter, 15-cm tall cylindrical shell with acoustic windows for TTE and an access port for a TEE probe. The interior contains 24 dual-modality targets, 5-mm in diameter, suspended in a three-turn helix occupying a volume that is similar to an adult heart. An ultrasound-compatible, tissue-mimicking slurry medium fills the remainder of the phantom. The dual-modality targets are agar based with barium sulfate (BaSO_4) powder and glass beads added to generate contrast in both x-ray and ultrasound. Appropriate concentrations of these additives were determined experimentally with contrast measurements in x-ray, CT, and ultrasound. Selected concentrations were 150 mg/mL BaSO_4 and 100 mg/mL of 53-63 μm diameter glass beads. Average target contrast (± SD) was 16% ± 2% in x-ray fluoroscopy (90 kV) and 1805 ± 99 HU in CT (100 kV). In ultrasound, target CNR was 4.30 ± 0.62 in 2D B-mode and 4.03 ±1.06 in 4D-mode images acquired at a center frequency of 2.8 MHz.
机译:经导管干预导管装置的心脏结构异常需求实时可视化及其与心脏解剖关系。超声心动图X射线荧光的共配准已经提出以提供用于这些程序的必要的设备和软组织可视化。实时三维X射线的发展/回波与设备跟踪登记系统已经阻碍了缺乏合适的测试模型的。这项研究提出一个幻象是与x射线,CT,经胸(TTE)相容,并且经食道回波(TEE),用于测试的新登记的解决方案的可行性和准确性。所述体模包括一个20.3厘米直径,15厘米高的圆柱形有用于TTE声窗和用于TEE探头的进入端口外壳。内部包含24双模态的目标,5毫米的直径,悬浮在三匝螺旋占据的体积是类似于成人心脏。超声兼容,仿组织浆介质填充的假体的其余部分。在双模态靶琼脂加入到生成在两个X射线和超声造影硫酸钡(BaSO_4)粉末和玻璃珠为主。这些添加剂的合适浓度与在X射线,CT和超声造影测量实验确定。选择的浓度分别为150毫克/毫升BaSO_4和100mg / 53-63的微米直径的玻璃珠毫升。平均目标对比度(±SD)为16%±2%在X射线荧光(90千伏)和1805±99 HU在CT(100千伏)。在超声,目标CNR为在2D B模式4.30±0.62和在2.8兆赫的中心频率下获取4D模式图像4.03±1.06。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号