首页> 外文会议>Image-Guided Procedures, Robotic Interventions, and Modeling >EpiGuide 2D: visibility assessment of a novel multi-channel out-of-plane needle guide for 2D point-of-care ultrasound
【24h】

EpiGuide 2D: visibility assessment of a novel multi-channel out-of-plane needle guide for 2D point-of-care ultrasound

机译:Epiguide 2D:用于2D护理点超声波的新型多通道外针导轨的可见性评估

获取原文

摘要

The desire to improve patient safety and clinical precision has prompted research in the development of a real-time, single operator, image-guided solution for neuraxial anesthesia. Ultrasound is ideal for this application given that it is real-time, non-ionizing, and with recent advances, ultra-portable. Previous work has investigated the use of 3D ultrasound and 2D in-plane imaging to track needle insertions but faced barriers to successful clinical translation. The EpiGuide 2D is a novel multi-channel out-of-plane needle guide that addresses deficiencies observed in prior designs. Specifically, it leverages beam thickness, an inherent imaging artefact, to provide needle visibility over a range of depths. The current work investigates the ability of the EpiGuide 2D to visualize out-of-plane needle insertions. Two different needle types are explored with 9 needle angles over 5 distinct imaging depths. Benchtop testing is performed to assess stability of the guide's open channels. Subsequent water bath testing is used to establish baseline visibility metrics across all angles. Finally, testing on an ex vivo porcine model is performed. A total of n=424 needle insertions are performed. Visible range and contrast-to-noise ratios are measured for each insertion. As needle angle approached parallel to the imaging plane, visible range increased. Needle echogenicity also increased the visible range of the needle in the water bath setting but was not found to have a statistically significant effect on visible range in the porcine model. The EpiGuide 2D accommodates needle visualization in tissue for depths of 21 mm to 53 mm. Further in vivo studies are warranted.
机译:提高患者安全性和临床精度的愿望促使研究了实时,单次运营商,用于神经麻醉的图像引导溶液的开发。超声波是本申请的理想选择,因为它是实时,非电离,以及最近的推进,超便携。以前的工作已经调查了使用3D超声波和2D面内成像来跟踪针插入,而是面临成功临床翻译的障碍。 EPIGUIDE 2D是一种新的多通道外针导轨,其解决了现有设计中观察到的缺陷。具体地,它利用光束厚度,固有的成像伪影,在一系列深度上提供针头可见性。目前的工作调查了ePiGuide 2D以可视化平面外针插入的能力。探索两种不同的针类型,具有9个针角度超过5个不同的成像深度。执行基台测试以评估指南开放通道的稳定性。随后的水浴测试用于建立所有角度的基线可见度指标。最后,执行对exVivo猪模型的测试。执行总共n = 424针插入。针对每个插入测量可见范围和对比度噪声比。作为与成像平面平行接近的针角,可见范围增加。针状升降性也增加了水浴环境中针的可见范围,但未发现对猪模型中的可见范围具有统计学显着的影响。 EPIGUIDE 2D适用于组织中的针眼,深度为21mm至53mm。进一步在体内研究得到保证。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号