Electrostatic Precipitators are usually put into service after a complete shut-off of oil supply to the boiler burners of the furnace of a coal-fired power plant. However, such practice may lead to enormous dust concentration in the flue gas (design value is 37.9 g/Nm3 at 50%RO load) and heavy black smoke appearing at the stack outlet during the oil and/or co-fuel firing condition of boiler. To minimize such problem, an experimental study on charging and electrostatic precipitator operation during unit start-up and shut-down was carried out to verify de-dusting performance. It requires the manual control of the secondary voltages to be lower than sparking voltage of 10~15kV in case of oil and/or co-fuel firing condition of boiler. The study results prove that the electrostatic precipitator runs normally with good de-dusting performance (about 56.4 mg/Nm3 at unit start-up and within 31 mg/Nm3 at unit shut-down) and meets the Vietnamese environmental emission requirements as per proposed specified rules. From the study results, it can be predicted that Electrostatic Precipitators (ESP) & Sea-Flue Gas Desulphurization System (FGD) may be kept running during house load operation and run-back modes. Also, with the ESP and FGD running, the coal-fired power plant may not be limited to the loading dispatch at stable loads under co-firing condition below the minimum load of anthracite coal firing as required from power system.
机译:静电除尘器通常在燃煤发电厂炉的锅炉燃烧器完全关闭后投入使用。然而,这种做法可能导致烟道气中的巨大粉尘浓度(设计值为37.9g​​ / nm 3 在50 %RO负载中,在锅炉的油和/或共燃料烧制条件下出现在堆叠出口处的重黑烟。为了最大限度地减少此类问题,进行了在单元启动和关闭期间充电和静电除尘器操作的实验研究,以验证去除尘性能。在锅炉的油和/或共燃料烧制条件的情况下,它需要对辅助电压的手动控制低于10〜15kV的火花电压。该研究结果证明,静电除尘器通常具有良好的去除尘性能(约56.4 mg / nm 3 在单位启动和31 mg / nm内 3 单位关闭)并根据拟议规定的规定达到越南环境排放要求。从研究结果来看,可以预测静电除尘器(ESP)和海烟气体脱硫系统(FGD)可以在房屋负载运行和循环模式下保持运行。此外,通过ESP和FGD运行,燃煤发电厂可能不限于在电力系统所需的烟火燃煤的最小载荷下的共用条件下在稳定载荷下装载调度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号