首页> 外文会议>IEEE International Conference on Power System Technology >Analysis on Spent Fuel Pool Monitoring System in Nuclear Power Plant after Fukushima Accident
【24h】

Analysis on Spent Fuel Pool Monitoring System in Nuclear Power Plant after Fukushima Accident

机译:福岛事故后核电站燃料池监测系统分析

获取原文

摘要

After the Fukushima accident, the National Nuclear Safety Agency (NNSA) issued "the general technical requirements for improving the operation of nuclear power plant after Fukushima Accident" (hereinafter referred to as "technical requirements"), which puts specific requirements on the spent fuel pool monitoring system. In this paper, the solutions for the spent fuel pool monitoring system are discussed in detail from the aspects of instrument setting, layout position and signal acquisition and display of active and passive nuclear power plants. Based on the technical requirements, the solutions for the spent fuel pool monitoring system of active and passive nuclear power plants were evaluated and analyzed. Three solutions for subsequent projects were proposed and compared. The conclusions and results of this paper can be used as an important reference and basis for the optimization and improvement of the technical solutions for the spent fuel pool monitoring system in nuclear power plants.
机译:在福岛事故发生后,国家核安全局(NNSA)发布了“福岛事故后改善核电站运作的一般技术要求”(以下简称“技术要求”),这对花费燃料进行了特定的要求池监控系统。本文从仪表设定,布局位置和信号采集和显示有源和被动核电厂的展示的方面,详细讨论了废燃料池监测系统的解决方案。基于技术要求,评估并分析了活性和被动核电厂的燃料池监测系统的解决方案。提出并比较了后续项目的三种解决方案。本文的结论和结果可作为优化和改进核电站燃料池监测系统技术解决方案的重要参考和依据。