Islanding operation at the sending terminal of Yunnan-Guangdong UHVDC transmission project was designed as one of the normal operation modes. In order to use this mode, it should be verified that the UHVDC and the islanding AC system can withstand impacts of various faults that may occur during real system operation. The DC system mono-polar blocking is one of the serious faults that the islanding operation must be able to withstand. Based on the islanding operation on-site commissioning tests, the fault recovery process after mono-polar blocking under rated DC power operation was analyzed. Using electromagnetic transient simulations, the resonance issue caused by shedding partial generation units in the islanding system for over-frequency control after the mono-polar blocking was investigated. The coordination control of tripping surplus reactive power compensation units at converter station and shedding partial generation units for improving the fault recovery characteristic was evaluated. The analysis supports the real system operation using islanding operation mode.
机译:云南 - 广东UHVDC传输项目发送端子的岛屿运营设计为正常运行模式之一。为了使用这种模式,应该验证UHVDC和岛地AC系统可以承受在真实系统操作期间可能发生的各种故障的影响。 DC系统单极块是岛屿操作必须能够承受的严重故障之一。基于岛屿运营现场调试测试,分析了在额定直流电源运行下单极堵塞后的故障恢复过程。采用电磁瞬态仿真,研究了在单极性阻断后脱落局部生成单位引起的局部生成单位引起的谐振问题。评估了转换器站跳闸剩余无功补偿单元的协调控制,用于改善故障恢复特性的脱落部分生成单元。该分析支持使用孤岛操作模式进行实际系统操作。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号