首页> 外文会议>International Ergonomics Association, Congress >Validation and Comparison of Three Positioning Protocols of Inertial Measurement Units for Measuring Trunk Movement
【24h】

Validation and Comparison of Three Positioning Protocols of Inertial Measurement Units for Measuring Trunk Movement

机译:验证及比较惯性测量单位测量躯干运动的定位协议

获取原文

摘要

Postures and movements of the trunk are of ergonomic concern when evaluating the risks at work. Technical measurement methods can be used for measurements of trunk movements for long duration with high accuracy, and are therefore increasingly used in practice and research. However, currently there is no standardized protocol for the sensor placement for trunk measurement. Three placement protocols of inertial measurement units (IMUs), including placement on C7, T4 and sternum (St), in combination with S1 spinous process, were compared with an optical motion capture (OMC) system. Four subjects performed a movement test including forward to backward bending, sideward bending and twisting of the trunk, and a symmetrical lifting task. Root-mean-square differences (RMSDs) and Pearson's correlation were calculated between the two systems. For the movement tests, the RMSDs of the forward inclination at the 10~(th), 50~(th) and 90~(th) percentiles from the three IMUs were all smaller than 7.3°. Larger differences were shown for C7 of the sideward inclination at 90~(th) percentile (10.8°). Also for the twisting, larger differences were shown, especially for C7-S1 and T4-S1 (RMSD= 16.5° and 19.8°). For the lifting tests of forward inclination, St had the smallest differences compared to OMC (RMSDs < 4.1°), while slightly larger errors were found for C7 and T4 at the 90~(th) percentile (RMSDs= 8.1° and 8.2°). Different positioning protocols seem to have a slightly different effect on the measurement accuracy of trunk movement. Considerations should be taken when comparing results across studies applying different protocols.
机译:在评估工作的风险时,躯干的姿势和运动是符合人体工程学的关注。技术测量方法可用于高精度的长期持续时间的躯干运动的测量,因此越来越多地用于实践和研究。但是,目前没有标准化方案用于中继测量的传感器放置。将三个惯性测量单元(IMU)的放置协议,包括在C7,T4和胸骨(ST)上与S1棘突组合的放置,与光学运动捕获(OMC)系统进行比较。四个受试者进行了运动测试,包括前向后弯曲,侧向弯曲和扭曲的躯干,以及一个对称的提升任务。在两个系统之间计算了根均方差异(RMSDS)和Pearson的相关性。对于运动测试,来自三个IMU的10〜(Th),50〜(Th)和90〜(Th)百分比的前向倾斜的RMSDS均小于7.3°。在90〜(Th)百分位数(10.8°)的侧向倾斜度的C7显示较大的差异。同样为扭曲,显示较大的差异,特别是对于C7-S1和T4-S1(RMSD = 16.5°和19.8°)。对于前向倾斜的提升测试,与OMC(RMSDS <4.1°)相比,ST具有最小的差异,而在90〜(TH)百分位数(RMSDS = 8.1°和8.2°),C7和T4发现略大的误差。不同的定位协议似乎对躯干运动的测量精度略有不同。在对应用不同协议的研究结果进行比较时,应考虑考虑因素。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号