首页> 外文会议>International Conference on Thermofluids >Effect of refrigerant charge variation of R32 as drop-in replacement for R22 in air conditioning system
【24h】

Effect of refrigerant charge variation of R32 as drop-in replacement for R22 in air conditioning system

机译:R32制冷剂充电变化的影响为空调系统R22的替代品

获取原文

摘要

Relatively, R32 has very low GWP compared to R22, and therefore leading R32 to be a potential substitute for R22. This paper investigates the performance changes due to drop-in replacement of R22 to R32 in a residential air conditioner. The liquid density ratio between R32 and R22 at 0°C is 0.82. As a result, theoretically, for drop-in 100% from R22 with R32, the refrigerant charge amount of R32 is 82% of R22 (by mass). In this experiment, the refrigerant charge mass of R32 is varied from 90% to 105% with 5% increment for each measurement. Experimental results show that the optimal refrigerant charge amount is 95%. At this optimal refrigerant charge amount, the mass ratio of R32 to R22 is 77.9%. Meanwhile, at this mass ratio, the cooling capacity increased by 7.7% and COP decreased by 12.1%.
机译:相对而言,与R22相比,R32具有非常低的GWP,因此导致R32是R22的潜在替代品。本文调查了住宅空调中R22至R32的替换因性能变化。 R32和R22在0℃之间的液体密度比为0.82。结果,从具有R32的R22从R 2 2滴入100%,R32的制冷剂电荷量为R22(质量)的82%。在该实验中,R32的制冷剂电荷质量在每次测量的5%增量的90%到105%时变化。实验结果表明,最佳的制冷剂电荷量为95%。在这种最佳的制冷剂电荷量,R32至R22的质量比为77.9%。同时,在这种质量比下,冷却能力增加7.7%,警察减少12.1%。