This paper aims to consolidate methods of measuring non-sinusoidal active energy systems, as well as to present the results of different tests carried out in several electricity meters available on the national market. The tests considered different voltage and current waveforms, for different harmonic distortion magnitudes. The results showed that there is currently a lack of consistency in the measurement of active energy for billing purposes. In this sense, measurement deviations greater than 50% were identified for certain voltage and current waveforms. All tested meters are available on the national market and are commonly used by electrical utility distributors for the billing process of low voltage consumers.
机译:本文旨在巩固测量非正弦活性能量系统的方法,以及呈现在全国市场上提供的几种电表中进行的不同测试的结果。测试被认为是不同的电压和电流波形,用于不同的谐波失真大小。结果表明,用于测量有效能量的计费目的,目前存在缺乏一致性。从这个意义上讲,针对某些电压和电流波形识别出大于50 %的测量偏差。所有测试仪表都在全国市场上提供,并且通常由电厂经销商用于低压消费者的计费过程。