首页> 外文会议>IIR international conference on sustainability and cold chain >PERFORMANCE EVALUATION METHOD OF HEAT PUMP DRIVEN REFRIGERATED DISPLAY CABINETS
【24h】

PERFORMANCE EVALUATION METHOD OF HEAT PUMP DRIVEN REFRIGERATED DISPLAY CABINETS

机译:热泵驱动冷藏橱柜的性能评估方法

获取原文

摘要

Annual heat load, energy consumption and COP of open refrigerated display cabinets (ORDC) driven byheat pump in supermarkets are assessed by means of a dedicated performance evaluation method. Thesystem modelling approach is firstly presented, and subsequently fitted to experimental data measured withinactual equipment working in a comprehensive range of operative conditions. The obtained characteristicequations for estimating the heat load of the ORDC and energy consumption of the condensing unit areemployed for a first screening of the results with reference to the effect of the display cabinet set temperature,refrigerant evaporating temperature and supermarket room temperature. Seasonal temperature distributionsof three representative locations are applied for the performance calculation of a selected arrangement of 5different models of ORDCs in a store. This methodology is integrated in a dedicated software, with a userfriendly interface, which is generally capable of predicting the annual performance of various combinationsof different ORDCs and can therefore be used for benchmarking and identifying energy conservationopportunities.
机译:由此开放式冷藏橱柜(旧版)的年热负荷,能耗和COP通过专用性能评估方法评估超市中的热泵。这首先呈现系统建模方法,随后安装在内部的实验数据实际设备在综合操作条件范围内工作。获得的特征用于估计煽动器的热负荷和冷凝单元的能量消耗的方程参考显示柜设定温度的效果,用于首次筛选结果,制冷剂蒸发温度和超市室温。季节性温度分布在三个代表位置应用于5的所选布置的性能计算在商店中的不同模型Ordcs。该方法与用户一起集成在专用软件中友好的界面,通常能够预测各种组合的年度表现因此,不同的旧兵器可以用于基准测试和识别节能机会。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号