An annual energy performance evaluation method for open refrigerated display cabinets (ORDC) driven by CO_2 heat pumps in supermarkets is established to predict the annual heat load, energy consumption, COP and total CO_2 emissions. Significant condition variations that affect the system performance are considered. The system is thermodynamically modelled with reference to the actual equipment. Experimental data at a comprehensive range of operative conditions are fitted then the characteristic equations for both the heat load of the ORDC and energy consumption of the condensing unit are obtained. The seasonal and climatic condition changes are accounted by integrating the available annual outdoor temperature data of the store location on the performance calculation. Relative error between the estimated energy consumption and experiment stays within ±20%. The constructed tool is capable of predicting the performance of multiple combinations of different ORDC types and can therefore be used for benchmarking, identifying energy conservation opportunities, and assessment of GHG emission.
机译:建立了超市用CO_2热泵驱动的开放式冷藏展示柜(ORDC)的年度能源性能评估方法,以预测年度热负荷,能耗,COP和CO_2总排放量。考虑了影响系统性能的重大条件变化。参照实际设备对系统进行热力学建模。拟合了各种操作条件下的实验数据,然后获得了ORDC的热负荷和冷凝单元能耗的特征方程式。通过将商店位置的可用年度室外温度数据整合到性能计算中来考虑季节和气候条件的变化。估计能耗与实验之间的相对误差保持在±20%以内。所构建的工具能够预测不同ORDC类型的多种组合的性能,因此可以用于基准测试,确定节能机会以及评估GHG排放量。