PLN have already implemented DGA for decades as a method to assess the condition of power transformers. PLN TJBT conducts DGA test annually on 448 units of transformers which consist of 500/150 kV, 150/70 kV, 150/20 kV and 70/20 kV voltages rate power transformers. To make an action based on DGA result, PLN use several references such as IEC 60599 and IEEE C57-104. IEC 60599 propose utilities to generate typical concentration values as a reference to determine which transformer are considered to be normal operated and abnormal operated in order to make a further action to the transformers. By using DGA test result of 448 power transformers in PLN TJBT, typical normal concentration values on each gas can be determined and compared with IEEE and IEC typical concentration values. The maximum concentration value between IEEE C57.104-2008, IEC 60599:2015 and PLN TJBT’s data on every gas almost showing the same level, except C2H2 gas where IEC 60599 have the highest value which is 20 ppm. PLN also use several methods i.e. ratios, key gases, Duval triangle and Duval pentagon to interpret DGA test result in order to know the fault type. This paper shows typical fault type among 448 units of power transformers in PLN TJBT including stray gassing possibilities.
机译:PLN已经实施了DGA几十年来评估电力变压器条件的方法。 PLN TJBT进行每年DGA测试上448个单位,其由一百五十○分之五百千伏,70分之150千伏,20分之150千伏和二十〇分之七十○千伏电压速率电力变压器的变压器。为了基于DGA结果进行动作,PLN使用诸如IEC 60599和IEEE C57-104等几个引用。 IEC 60599提出公用事业公司以产生典型的浓度值作为参考,以确定哪个变压器被认为是正常操作和异常操作的,以便对变压器进行进一步的动作。通过在PLN TJBT中使用448电力变压器的DGA测试结果,可以确定每个气体上的典型正常浓度值,并与IEEE和IEC典型浓度值进行比较。 IEEE C57.104-2008,IEC 60599:2015和PLN TJBT之间的最大浓度值与几乎显示相同水平的每个气体,除了IEC 60599具有20 ppm的最高值。 PLN还使用几种方法I.。比率,关键气体,杜瓦尔三角形和杜瓦尔五角大楼来解释DGA测试结果,以了解故障类型。本文在PLN TJBT中显示了448个电源变压器中的典型故障类型,包括流浪的吸气可能性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号