In this paper, a conceptual and practical approach for total lightning protection system based on the MS/IEC requirements on Ground-mounted Photovoltaic lightning protection system are discussed. The test site is located at the Renewable Energy Research Office (RERO) Faculty of Engineering UPM Serdang, Malaysia with installed capacity of 10 kWp Monocrystalline PV modules c/w Sun Grow Inverter/ Data logging system. Lightning current which passes through the common lightning protection system may still dispersed and affect the ground-mounted PV power system mainly due to the uncertainties of point-of-strike. Hence the uniqueness of this project is the strategic structure bonding of PV systems with wind turbine (external pole) and perimeter fencing to achieve a good common earthing configuration. The protection system is also equipped with Surge Protection Devices (SPD) based on the zonal protection scheme to protect the site from both direct and indirect damages of lightning, with special attention to the protection of PV panels and inverters.
机译:本文讨论了基于MS / IEC对接地光伏防雷系统的MS / IEC要求的总防雷系统的概念和实用方法。该测试网站位于可再生能源研究办公室(RERE)工程UPM Serdang,马来西亚装机容量为10 kWp单晶光伏模块C / W SUN变频器/数据测井系统。穿过公共防雷系统的雷电电流仍然可以分散并影响地安装的光伏电力系统,主要是由于撞击点的不确定性。因此,该项目的独特性是PV系统与风力涡轮机(外极)和周边击剑的战略结构键合,以实现良好的常见接地配置。保护系统还配备了基于区域保护方案的浪涌保护装置(SPD),以保护地点免受闪电的直接和间接损坏,特别注意PV面板和逆变器的保护。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号