首页> 外文会议>International Conference on Advanced Functional Materials >Investigation of Flux-Less Soldering of Metal Matrix Composite and Ceramics by Use of Zn Solder
【24h】

Investigation of Flux-Less Soldering of Metal Matrix Composite and Ceramics by Use of Zn Solder

机译:使用Zn焊料调查金属基质复合材料和陶瓷的焊剂焊接

获取原文

摘要

The work was dealing with direct soldering of Al_2O_3 ceramics and a metal/ceramic composite (MMC) with Al matrix. The joints were fabricated by application of flux-less process by use of a hot plate at the assistance of ultrasound with frequency of 40 kHz. The experiments were performed by use of Zn6Al6Ag solder. Wetting was attained on both substrates. The joints of a good quality were fabricated. The soldering temperature was 420 °C. The microstructural studies of interface have revealed a transient zone of Al dissolving on the side of MMC and formation of Zn oxides on the side of ceramics, which were responsible for bond formation.
机译:该作品用Al基质处理Al_2O_3陶瓷和金属/陶瓷复合物(MMC)的直接焊接。通过在超声的频率为40kHz的超声波的辅助下使用热板,通过使用热板来制造接头。通过使用Zn6AL6AG焊料进行实验。在两个底物上达到润湿。制作了良好质量的关节。焊接温度为420℃。界面的微观结构研究揭示了溶解在MMC侧面的Al瞬态区,并在陶瓷侧形成Zn氧化物,其负责键形成。