Four perception experiments are reported, in which a typical office environment was simulated, and the acceptability of the stroboscopic effect was measured, expressed as the percentage of people annoyed with the effect as a function of Stroboscopic effect Visibility Measure value. A limit of SVM = 1.5 is proposed. Based on the results, a functional relationship is provided, which can be used as a first proposal for the stroboscopic effect acceptability in different applications.
机译:报告了四种感知实验,其中模拟了典型的办公环境,并测量了触摸镜效果的可接受性,表达了人们因触摸镜效应可见度量值的函数而令人讨厌的人令人讨厌的百分比。 提出了SVM = 1.5的极限。 基于该结果,提供了一种功能关系,其可以用作不同应用中的频闪效果可接受性的第一个提议。