首页> 外文会议>Nordic Symposium on Building Physics >Seasonal optimization of a fixed exterior complex fenestration system considering visual comfort and energy performance criteria
【24h】

Seasonal optimization of a fixed exterior complex fenestration system considering visual comfort and energy performance criteria

机译:考虑视觉舒适性和能源性能标准的固定外部复杂更敏感系统的季节性优化

获取原文
获取外文期刊封面目录资料

摘要

In a certain climate, the lighting and thermal performance of a building can be improved if the position of a fixed solar protection system of a complex fenestration system (CFS) is changed according to the period of year. The main objective of this paper is to optimize the lighting and energy performance of a fixed exterior horizontal and curved perforated louver used on a fully glazed facade of an office space located in Santiago (Chile) and Oslo (Norway), considering different slats angles of the CFS, depending of the season of the year. Bi-monthly, quarterly and bi-annual position of the CFS has been evaluated. The highest reduction of the total energy consumption corresponds to the bi-annual and quarterly cases in Santiago with 11.6% with respect to the annual case, and the quarterly case in Oslo with 8.3% with respect of annual case.
机译:在某种气氛中,如果根据一年期间改变了复杂的更换系统(CFS)的固定太阳能保护系统的位置,则可以提高建筑物的照明和热性能。本文的主要目的是优化固定的外部水平和弯曲穿孔百叶窗的照明和能量性能,用于位于圣地亚哥(智利)和奥斯陆(挪威)的办公空间的完全玻璃门面,考虑到不同的板条角度CFS,取决于今年的季节。评估了CFS的双月,季度和双年度职位。总能源消耗的最高减少对应于圣地亚哥的双年度和季度案件,同等年度案件11.6%,奥斯陆的季度案件涉及年度案件的8.3%。