Determination of the reference position in the near-infrared non-invasive blood glucose measurement in vivo

机译:在体内测定近红外非侵入性血糖测量中的参考位置

获取原文

摘要

Position-based reference measurement method is taken as one of the most promising method in non-invasive measurement of blood glucose based on spectroscopic methodology. Selecting an appropriate source-detector separation as the reference position is important for deducting the influence of background change and reducing the loss of useful signals. Our group proposed a special source-detector separation named floating-reference position where the signal contains only background change, that is to say, the signal at this source-detector separation is uncorrelated with glucose concentration. The existence of floating-reference position has been verified in a three layer skin by Monte Carlo simulation and in the in vitro experiment. But it is difficult to verify the existence of floating-reference position on the human body because the interference is more complex during in vivo experiment. Aiming at this situation, this paper studies the determination of the best reference position on human body by collecting signals at several source-detector separations on the palm and measuring the true blood glucose levels during oral glucose tolerance test (OGTT) experiments of 3 volunteers. Partial least square (PLS) calibration model is established between the signals at every source-detector separation and its corresponding blood glucose levels. The results shows that the correlation coefficient (R) between 1.32 mm to 1.88 mm is lowest and they can be used as reference for background correction. The signal of this special position is important for improving the accuracy of near-infrared non-invasive blood glucose measurement.
机译:基于位置的参考测量方法作为在基于分光方法血糖的非侵入式测量的最有前途的方法之一。选择适当的源 - 检测器间隔作为基准位置为扣除背景变化的影响并降低有用信号的损失重要。我们小组提出命名浮动基准位置的特殊源 - 检测器分离,其中信号仅包含背景的变化,也就是说,在该源 - 检测器分离的信号是不相关的葡萄糖浓度。浮动基准位置的存在已经在通过蒙特卡罗模拟,并在体外实验中的三层皮肤得到了验证。但它是难以核实浮动基准位置的存在对人体,因为干扰体内实验过程更加复杂。针对这一情况,本文通过在对掌几个源 - 检测器间距采集信号和中的3名志愿者口服葡萄糖耐量试验(OGTT)实验测定真实血糖水平研究对人体的最佳基准位置的确定。偏最小二乘(PLS)校准模型在每个源 - 检测器分离的信号和与其对应的血糖水平之间建立。结果表明,以1.88毫米1.32毫米之间的相关系数(R)是最低的,并且它们可以用作用于背景校正参考。这个特殊的位置的信号是用于提高近红外非侵入血糖测量的准确度很重要。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号