Armature resistance and electromotive force can be identified by conventional DC test and no load test. However, such conventional test method can not be used for measurement of d-axis and q-axis inductances. Authors propose to apply single-phase small AC-voltage as measurement voltage source into three phase winding connected as the proposed circuit to identify the two inductances by fixing mover to certain position. The proposed method is explained in detail and verified by numerical and experimental case studies.
机译:通过常规的DC测试和无负载测试可以鉴定电枢电阻和电动势。然而,这种传统的测试方法不能用于测量D轴和Q轴电感。作者建议将单相小交流电压作为测量电压源应用于连接作为所提出的电路的三相绕组,以通过将动器固定到某些位置来识别两个电感。所提出的方法详细解释并通过数值和实验案例研究验证。