首页> 外文会议>モータドライブ研究会;マグネティックス研究会;リニアドライブ研究会 >Characteristic Test Method of Linear Synchronous Generator Using Single-phase AC-voltage with Various Frequency
【24h】

Characteristic Test Method of Linear Synchronous Generator Using Single-phase AC-voltage with Various Frequency

机译:线性变频发电机单相交流电压特性测试方法

获取原文

摘要

Armature resistance and electromotive force can be identified by conventional DC test and no load test. However, such conventional test method can not be used for measurement of d-axis and q-axis inductances. Authors propose to apply single-phase small AC-voltage as measurement voltage source into three phase winding connected as the proposed circuit to identify the two inductances by fixing mover to certain position. The proposed method is explained in detail and verified by numerical and experimental case studies.
机译:电枢电阻和电动势可以通过常规的直流测试和空载测试来识别。但是,这种常规测试方法不能用于测量d轴和q轴电感。作者建议将单相小交流电压作为测量电压源施加到作为拟议电路连接的三相绕组中,以通过将动子固定在特定位置来识别两个电感。对该方法进行了详细的解释,并通过数值和实验案例研究进行了验证。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号