首页> 外文会议>International Symposium on Heating, Ventilation and Air Conditioning >Influence of occupant behaviour on oversizing issue of heat pumps for residential district in Hot Summer and Cold Winter zone of China
【24h】

Influence of occupant behaviour on oversizing issue of heat pumps for residential district in Hot Summer and Cold Winter zone of China

机译:中国炎热夏季寒冷冬区居住区热泵超大泵出版的影响

获取原文

摘要

A key aspect of Ground source heat pump (GSHP) is sizing of capacity, which has a signifi-cant influence on energy efficiency, energy consumption and initial investment of system. The capacity of heat pump for residential district should be consistent with cooling and heating load of residential district. However, field measurements and spot interviews indicate that the oversizing issue of GSHP is common for residential district in Hot Summer and Cold Winter zone. The current method of designing the capacity does not take the influence of occupant behavior into consideration. This paper establishes the model by DeST (Designer's Simulation Toolkits) software considering the different occupant behavior with different Air-conditioning unit (AC) units and it recommends designing the different capacity of the GSHP systems with different types of AC units.
机译:地面源热泵(GSHP)的一个关键方面是容量的尺寸,具有对能效,能耗和系统初始投资的显着影响。住宅区的热泵容量应符合住宅区的冷却和加热负荷。然而,现场测量和现货访谈表明,GSHP的超大问题对于炎热的夏季和寒冷的冬季区的住宅区是常见的。目前设计能力的方法不会考虑占用行为的影响。本文通过Dest(Designer的仿真工具包)软件建立了模型,考虑不同空调单元(AC)单元的不同占用行为,它建议使用不同类型的AC单元设计GSHP系统的不同容量。