Introduction: As one of the pilot cities for renewable energy application, which is defined by Ministry of Housing and Urban-Rural Construction of the People's Republic of China, Shenyang has widely popularized and applied GSHP(Ground Source Heat Pump) technology in winter heating and summer cooling. Methods: This paper uses the GSHP system of a residential district of Shenyang as an example to investigate, test and analyze the GSHP project. The test of the indoor temperature and humidity should be done after the buildings have achieved stable thermal. Conclusions: The system had stable performance, which benefited the system to have long-term operation. Compared with traditional air conditioner, the operation cost of GSHP was lower and it saves about 21.39% annual operation cost, which leads to the result that GSHP is economic and energy saving. The paper focuses on the experimental verification, needs further simulation software to calculate the results. This project was financially supported by the National science and technology support plan sub-topic (2011BAJ05B01-04).
机译:介绍:作为可再生能源应用的试点城市之一,由中华人民共和国人民共和国的住房和城乡建设部定义,沉阳在冬季加热中广泛推广和应用GSHP(地面源热泵)技术夏季冷却。方法:本文采用沉阳住宅区的GSHP系统作为调查,测试和分析GSHP项目的示例。在建筑物实现稳定的热量之后,应进行室内温度和湿度的测试。结论:该系统的性能稳定,使系统具有长期运行。与传统空调相比,GSHP的运营成本较低,其年度运营成本下降了约21.39%,这导致GSHP是经济和节能的结果。本文侧重于实验验证,需要进一步的仿真软件来计算结果。该项目由国家科学和技术支持计划分组(2011BAJ05B01-04)进行财务支持。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号