The Impact of Relative Humidity on the Emission Behaviour of Formaldehyde in Building Materials

机译:相对湿度对建筑材料中甲醛排放行为的影响

获取原文
获取外文期刊封面目录资料

摘要

Relative humidity (RH) is one of the main environmental factors affecting the emission behaviours of formaldehyde from building materials. Meanwhile, the initial emittable concentration (C_(m.0)) is proved to be the most sensitive key parameter to the emission behaviours. However, there is no report on the relationship between RH and C_(m.0) In this paper, C_(m.0) of formaldehyde from a type of medium density fiberboard in RH range of 20%-85% were tested by the ventilated C-history method. Experimental results show that C_(m.0) increased by 10 times when RH rising from 20% to 85%. A linear relationship between ln(C_(m.0)) and RH is obtained based on the experimental results. A correlation characterizing the association of emission rate and RH is also derived. With the correlations, the C_(m.0) emission rate different from test RH conditions can be conveniently obtained. This study should be useful for predicting the emission characteristics under varied RH conditions.
机译:相对湿度(RH)是影响来自建筑材料的甲醛排放行为的主要环境因素之一。同时,被证明是排放行为最敏感的关键参数(C_(M.0))。然而,本文中没有关于RH和C_(M.0)之间的关系的报道,通过RH范围为20%-85%的培养基密度纤维板的甲醛的C_(M.0)。通风的C历史方法。实验结果表明,当RH从20%升至85%时,C_(M.0)增加了10倍。基于实验结果获得LN(C_(M.0))和RH之间的线性关系。还导出了表征发射率和RH的关联的相关性。通过相关性,可以方便地获得与测试RH条件不同的C_(M.0)发射率。该研究应该有助于预测变化Rh条件下的排放特性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号