首页> 外文会议>International Building Physics Conference >An Analysis of the Impact of Heat Pump Systems on Load Matching and Grid Interaction in the Canadian Context
【24h】

An Analysis of the Impact of Heat Pump Systems on Load Matching and Grid Interaction in the Canadian Context

机译:热泵系统对加拿大背景下负载匹配和电网互动的影响分析

获取原文

摘要

This paper presents an examination of heat pump systems in single family Canadian homes from a load matching and grid interaction perspective. First, a detailed energy model of a high performance single family home equipped with a PV array is developed for two Canadian regions (Toronto and Vancouver). This energy model then serves as a base for three distinct heat pump systems, ranging from a conventional air-source heat pump to a ground-source heat pump with limited thermal storage capacity. Results are examined both in terms of the HVAC system and the total performance of the home in order to fully describe the potential impact of heat pumps as a means of improving the building/grid interaction.
机译:本文从负载匹配和电网交互角度看,对单家族加拿大家庭中热泵系统进行了检查。首先,为两个加拿大地区(多伦多和温哥华)开发了配备有光伏阵列的高性能单户家庭的详细能量模型。然后,该能量模型用作三个不同的热泵系统的底座,从传统的空气源热泵到具有有限的热存储容量的地源热泵。结果在HVAC系统方面和家庭的总性能方面进行了检查,以完全描述热泵作为提高建筑物/电网相互作用的手段的潜在影响。