Heat transfer and pressure drop in an all-welded plate heat exchanger with ripples have been experimentally investigated in this paper. The ripples were corrugated by the way of special machine. The heat transfer coefficient and pressure drop was experimented, and also calculated by the wall temperature method. The flow of water inside the plate heat exchanger was arranged as a single-pass and countercurrent. The hot water and cold water inlet temperatures were maintained at around 50°C and 35°C, respectively, while the hot oil and cold water inlet temperatures were got at about 40°C and 35°C, respectively. It indicated that the overall heat transfer coefficient calculated by wall temperature method fitted the actual value.
机译:在本文实验研究了全焊接板式热交换器中的热传递和压力下降。涟漪通过特殊机器的方式波纹。传热系数和压降进行了实验,并且还通过壁温法计算。板材热交换器内的水流被布置为单通过和逆流。热水和冷水入口温度分别保持在约50℃和35℃,而热油和冷水入口温度分别在约40℃和35℃。它表明,通过壁温法计算的总传热系数拟合实际值。