Controlling both input and output sides of the direct matrix converter using predictive control implies high computational cost due to the fact that it has twenty-seven available switching states and the needed of weighting factors. In this paper, an indirect model predictive current control strategy is proposed in order to simplify the computational cost while avoiding the use of weighting factors. The method is based on the fictitious dc-link concept, which has been used in the past for the classical modulation and control techniques of the direct matrix converter. Simulated results confirm the feasibility of the proposal proving that it is an feasible alternative to classical predictive control strategies in this converter.
机译:使用预测控制控制直接矩阵转换器的两个输入和输出侧意味着由于它具有二十七种可用的交换状态和加权因子所需的事实,因此可以提高计算成本。在本文中,提出了一种间接模型预测电流控制策略,以简化计算成本,同时避免使用加权因子。该方法基于虚拟DC-LINK概念,该概念已经过去用于直接矩阵转换器的经典调制和控制技术。模拟结果证实该提案的可行性证明这是该转换器中经典预测控制策略的可行替代方案。