The pipeline drain point which is at an unapproachable location is a problem to check a leakage by common techniques such as soap test and ultrasonic leak test. Acoustic emission is an advantageous technique to be applied for solution to this case. The sensitivity, acoustic attenuation, acoustic signal character, and background noise are the main factors considered in this chapter. The laboratory and field experiments were done for collection of AE signal. In laboratory, the leak rate was simulated by roughly loose an end cap of drain point for 300 and 600 main pipe diameter. The characteristics of acoustic signal emitted by leakage and background noise were revealed by time and frequency domain analysis. The experimental results showed that the minimum detectable atmosphere leak rate at 10 m far from a wideband AE sensor was 20 ml/s which has the frequency response at 100 kHz. The acoustic characters of drain leakage and field background noise are the benefits for development of a portable device of leak inspection in the field.
机译:在未放弃位置处的管道排水点是通过诸如肥皂测试和超声波泄漏测试等常用技术来检查泄漏的问题。声发射是应用于这种情况的有利技术。灵敏度,声学衰减,声学信号字符和背景噪声是本章中考虑的主要因素。为收集AE信号进行实验室和现场实验。在实验室中,通过大致松开漏极点的端盖300和600主管直径来模拟泄漏率。通过时间和频域分析揭示了泄漏和背景噪声发出的声学信号的特性。实验结果表明,距宽带AE传感器10米的最小可检测气氛泄漏率为20mL / s,其具有100kHz的频率响应。排水泄漏和现场背景噪声的声学特征是开发现场泄漏检查的便携式设备的益处。