Based on semiconductor process conditions such as power, gas, temperature and pressure, proper elastomer seal material selection is vital to maximizing the performance and productivity of wafer process production systems. Numerous metrology and test methods are used to measure the combined performance of elastomer seals. It is extremely important to take into consideration several performance parameters because minute shifts or modifications to process conditions can have detrimental effects on the production process. Weight loss, FTIR, SEM, Laser Confocal Microscope, and ICP/MS are some of the test methods used by Greene, Tweed to predict, with high confidence, the performance of elastomer seals for specific process conditions. This methodology is used to support the semiconductor research and process development community.
机译:基于电力,气体,温度和压力等半导体工艺条件,适当的弹性体密封材料选择对于最大化晶片工艺生产系统的性能和生产率至关重要。许多计量和测试方法用于测量弹性体密封件的组合性能。考虑到几个性能参数非常重要,因为微小的换档或对过程条件的修改可能对生产过程产生不利影响。体重减轻,FTIR,SEM,激光共焦显微镜和ICP / MS是Greene,TWEED用于预测的一些试验方法,具有高置信性,弹性体密封件用于特定工艺条件的性能。该方法用于支持半导体研究和过程开发社区。