We used in this work electrodialysis (ED) to remove the iron (II) ions of sulfuric acid pickling bath. This technique has proven very useful and effective in our study. Indeed, it allowed us to demonstrate the effect of various parameters (current density, the nature of the membrane and the concentration of Fe (II)) on the efficiency of the electrodialysis process. The results obtained show that the treatment rate increases with increasing the current density in the range 1 to 20 mA.cm~(-2). However, increasing up to 30 mA.cm~(-2) led to a clogging of the membrane, involving a substantial increase in the electrical resistance of the system. Moreover the increase in concentration of iron ions in the feed compartment to 52g.L~(-1) improves the purification rate 70.17%. The study of the influence of the membrane nature has shown that the CMX membrane more effectively than CMV and two Nafion 117 membranes. In parallel with the treatment process is also studied the possibility to refocus sulfuric acid was studied a removal mechanism iron ions and sulfates of the study define the solution for species that might exist in the system Fe -H2SO4 - H2O. It is clear from this analysis that the purification of the solution (Fe (II) -H2SO4) processing will be based on the elimination of Fe~(2+) ions and HSO_4~-. A purification mechanism of the solution based on the transfer of species through the ion exchange membranes has been proposed.
机译:我们在这项工作中使用电渗析(ED)以除去硫酸酸洗浴的铁(II)离子。这项技术在我们的研究中证明非常有用和有效。实际上,它使我们能够证明各种参数(电流密度,膜的性质以及Fe(II)的浓度)的效果对电渗析方法的效率。得到的结果表明,处理速率随着1至20mACM〜(-2)范围内的电流密度而增加。然而,增加到30 mA.cm〜(-2)导致膜的堵塞,涉及系统的电阻大幅增加。此外,进料室中的铁离子浓度的增加提高了70.17%的纯化率。对膜性质的影响的研究表明,CMX膜比CMV更有效,两种Nafion 117膜更有效。与处理过程平行,还研究了重新聚焦硫酸的可能性,研究了一种去除机制铁离子和研究的硫酸盐定义了系统Fe-H 2 SO 4-H 2 O中可能存在的物种的溶液。从该分析中可以清楚地看出,溶液(Fe(II)-H2SO4)加工的纯化将基于消除Fe〜(2+)离子和HSO_4〜 - - 。提出了基于通过离子交换膜的物质转移的溶液的纯化机理。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号