首页> 外文会议>ISES EuroSun 2014 Conference >Evaluation of Dynamic Operation Effects for a Heat Pump in a Solar Combi-Plus System
【24h】

Evaluation of Dynamic Operation Effects for a Heat Pump in a Solar Combi-Plus System

机译:太阳能组合系统中热泵动态运行效果的评价

获取原文
获取外文期刊封面目录资料

摘要

Real-like –dynamic- working conditions shall be taken into account in the assessment of the seasonal performance of thermal system, particularly when these are driven by renewable energy sources. A vapour compression reversible heat pump installed in a solar combi-plus system was studied to verify the influence of variable sources and loads on the overall performance. The machine was tested in laboratory, following a dynamic sequence, which reproduces the seasonal real-like boundary conditions. The results of the dynamic test highlight the non-negligible influence of dynamic working conditions on the seasonal performance of the heat pump. Two unfavourable factors were identified, i.e. the presence of many on-off cycles during cooling mode and fast variations of the boundary condition – i.e. changing of set points in switching the operation from space heating to domestic hot water preparation. Given the importance of correctly evaluating these aspects, a short dynamic test procedure was developed and validated. This allows the evaluation of the seasonal performance of the heat pump, as far as the frequency distribution of the machine performance.
机译:在评估热系统的季节性性能时,应当考虑实际更好的工作条件,特别是当这些由可再生能源驱动时。研究了安装在太阳能组合系统中的蒸汽压缩可逆热泵,以验证可变源的影响和负载对整体性能的影响。通过动态序列,在实验室进行测试,该机器在动态序列之后再现季节性实际边界条件。动态测试的结果突出了动态工作条件对热泵季节性性能的不可忽略的影响。鉴定了两个不利因素,即冷却模式期间存在许多开关循环和边界条件的快速变化 - 即,在从太空加热到国内热水制备时改变设定点。鉴于正确评估这些方面的重要性,开发并验证了短动态测试程序。这允许评估热泵的季节性性能,只要机器性能的频率分布就可以。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号