During a recent turnaround at Mosaic's St. James Ammonia Plant, a plant incident during the LTS reduction caused the pressure drop across the primary reformer to triple. Mosaic and Clariant Technical Services worked together to determine the cause of the primary reformer pressure drop increase and implement procedures to attempt salvaging the charge of reforming catalyst. This paper will discuss the troubleshooting that was completed, remedial action attempted, safety precautions taken following the shutdown to make sure the primary reformer and LTS were started back up safely, and lessons learned.
机译:在马赛克圣詹姆斯氨厂的最近转变期间,在LTS减少期间发生的植物事件导致初级重整器的压力降至三倍。马赛克和克拉特的技术服务共同努力,确定初级重整压力下降的原因增加,实施程序以试图挽救重整催化剂的电荷。本文将讨论完成的故障排除,尝试的补救措施,关闭后采取的安全预防措施,以确保首发重整器和LTS安全地开始备份,并了解的经验教训。