摘要

During a recent turnaround at Mosaic's St. James Ammonia Plant, a plant incident during the LTS reduction caused the pressure drop across the primary reformer to triple. Mosaic and Clariant Technical Services worked together to determine the cause of the primary reformer pressure drop increase and implement procedures to attempt salvaging the charge of reforming catalyst. This paper will discuss the troubleshooting that was completed, remedial action attempted, safety precautions taken following the shutdown to make sure the primary reformer and LTS were started back up safely, and lessons learned.
机译:在Mosaic的St. James氨工厂的最近一次转机期间,LTS减少期间发生的工厂事故导致一次重整装置的压力下降了三倍。马赛克和科莱恩技术服务部门共同努力,确定重整器主压降增加的原因,并实施程序以挽救重整催化剂的进料。本文将讨论已完成的故障排除,尝试的补救措施,关闭后采取的安全预防措施,以确保主重整炉和LTS安全启动,并汲取了教训。