One of the important aspects of the power quality in electric power distribution and transmission networks is estimation of the light flicker caused by voltage variations. International standards governing design of power quality recording devices and various standards for evaluating power quality include model-based estimation of visual discomfort using UIE/IEC Flickermeter. Newer standards also use assessment of Rapid voltage changes (RVC) - computationally simplified but yet less precise model. Both models are based on the discomfort level reported by test subjects, which limits them on perceivable disturbances. However, many studies indicate that light flickering may cause number of physiological effects even when affected individual is not aware of the disturbance: headaches, eyestrain, decreased performance, interference with cortical processes, seizures etc. Some of these potential effects require further detailed research, but all of them should be considered as a topic in future development of the power quality standards.
机译:电力分配和传输网络中的电力质量的重要方面是由电压变化引起的光闪烁的估计。电力质量记录设备设计的国际标准和评估电能质量的各种标准包括使用UIE / IEC Flickermeter的视觉不适估算。较新的标准还使用快速电压变化(RVC)的评估 - 计算上简化但较低的模型。两种模型都基于测试对象报告的不适水平,这限制了它们可感知的干扰。然而,许多研究表明,即使受影响的个体不了解干扰,也可能导致生理效果的次数:头痛,眼泪,降低性能,干扰皮质过程,癫痫发作等。一些这些潜在效果需要进一步详细的研究,但所有这些都应被视为未来发展电能质量标准的主题。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号