Constant current source is one of crucial components of every bioimpedance measurement device. Here we present an analysis of a single supply current source based on a modified Howland circuit. The analysis of track to track capacitances has been performed by finite element numerical device simulation and compared to measurements on developed PCB without soldered elements. Capacitances of the order of 1 pF were simulated/measured the largest being the voltage source to ground capacitance (3 pF). The measured transconductance bandwith was about 3 MHz at 100 O load and 100 kHz at 100 kO. Circuit analysis with Spice resulted in larger bandwidths compared to the measured ones.
机译:恒流源是每个生物阻抗测量装置的关键部件之一。在这里,我们对基于修改的霍兰电路的单电源电流源进行了分析。通过有限元数值装置仿真进行了对轨道跟踪电容的分析,并与没有焊接元件的开发PCB的测量相比。模拟/测量1PF的电容的电容是接地电容的电压源(3 PF)的最大值。测量的跨导带宽在100°O负荷下为约3MHz,100kHz在100kO时。与测量的电路分析用Spice导致较大的带宽。