In this article, the fire risk of aluminium conductors which were in poor contact and short circuit of low-voltage were validated. Meanwhile, the temperature of aluminium droplets which were falling during experiments was measured. As a result, it showed that the common combustible, such as hay, cotton, paper and polyurethane foam can be ignited under bad contact and short conditions, which aimed to provide the important references for exploring the fire scene and investigating the reasons of electrical fires once the relevant evidences existed.
机译:在本文中,验证了铝导体的火灾风险和低电压短路的铝导体。同时,测量在实验期间落下的铝液滴的温度。结果表明,常见的可燃,如干草,棉,纸和聚氨酯泡沫可以在不良接触和短条件下点燃,旨在为探索火灾场景和调查电火灾原因提供重要的参考一旦相关证据存在。