首页> 外文会议>International Conference on Performance-based Fire and Fire Protection Engineering >Ignition Properties of Panels Coated with Finishing Fire-Retardant Paints under External Radiation
【24h】

Ignition Properties of Panels Coated with Finishing Fire-Retardant Paints under External Radiation

机译:涂有整理防火涂料的面板的点火性能下外辐射

获取原文

摘要

By utilizing the self-designed test platform to carry out tests on the edge ignition time and center ignition time of wooden panels coated with finishing fire-retardant paints to different fire-retardant degrees and analyzing the factors affecting the edge ignition time and center ignition time, this paper proposes the indicators for the assessment of fire-retardant properties of wooden panels coated with finishing fire-retardant paints, i.e. the edge ignition time and the center ignition time. It is indicated by research results that the paint quality, coating process and fire-retardant properties of wooden panels coated with finishing fire-retardant paints can be comprehensively assessed in terms of these two indicators; the edge ignition time can be used for auxiliary assessment of the quality situation of finishing fire-retardant paints, and the center ignition time can be used for assessment of the coating process of finishing fire-retardant paints.
机译:通过利用自动设计的测试平台来对涂有整理阻燃涂料的木板的边缘点火时间和中心点火时间进行测试,并分析影响边缘点火时间和中心点火时间的因素本文提出了评估涂层涂有焊接涂料的木板阻燃性能的指标,即边缘点火时间和中心点火时间。通过研究结果表明,在涂有整理阻燃涂料的木板的涂料质量,涂层工艺和阻燃性能可以在这两个指标方面全面评估;边缘点火时间可用于辅助评估造成防火涂料的质量情况,中心点火时间可用于评估整理阻燃涂料的涂层过程。

著录项