首页> 外文会议>Symposium on Next-generation thermal insulation challenges and opportunities >Standard Reference Material 1450d, Fibrous Glass Board, for Thermal Insulation Measurements
【24h】

Standard Reference Material 1450d, Fibrous Glass Board, for Thermal Insulation Measurements

机译:标准参考材料1450D,纤维玻璃板,用于隔热测量

获取原文

摘要

Thermal conductivity measurements at and near room temperature are presented as the basis for certified values of thermal conductivity for Standard Reference Material 1450d, Fibrous Glass Board. The measurements have been conducted in accordance with a randomized full factorial experimental design with two variables, bulk density and temperature, using the National Institute of Standards and Technology 1016 mm line-heat-source guarded-hot-plate apparatus. The thermal conductivity of the specimens was measured over a range of bulk densities from 114 to 124kg/m~3 and mean temperatures from 280 to 340 K. Uncertainties of the measurements, consistent with current international guidelines, have been prepared. A summary of the physical properties and associated analyses of Standard Reference Material 1450d are presented.
机译:在室温和接近室温的导热测量作为标准参考材料1450D,纤维玻璃板的导热系数的认证值的基础。使用全国标准和技术研究所的1016mm线 - 热源防护 - 热板装置,根据随机的完整因子实验设计进行了测量,其具有两个变量,散装密度和温度。在114至124kg / m〜3的一系列堆积密度范围内测量样品的导热系数,平均温度为280至340 k.测量的不确定性,符合目前的国际指南。提出了标准参考材料1450d的物理性质和相关分析的概述。