Partial discharge (PD) is considered as one of the major problem which harms the insulation of power cable. The authors have been developing a new measurement method for measuring PD in long-distance cable line using capacitive coupling electrodes. In this method, the PD signal was detected by the newly proposed capacitive coupling electrodes between a shielding layer and an additional foil electrode. In this paper, firstly, the proposed method was applied to detect PD using a communication cable line and the sensitivity was determined as 100 pC. Secondly, a simple PD monitoring device was fabricated using a pulse counter and the performance was satisfactory. Finally, an attempt has been made to understand the effect of the coupling capacitor on detection intensity. Also, the PD detection sensitivity for power cable under different installation conditions was analyzed.
机译:局部放电(PD)被认为是损害电力电缆绝缘的主要问题之一。作者一直在开发一种新的测量方法,用于使用电容耦合电极在长距离电缆线中测量PD的测量方法。在该方法中,通过屏蔽层和附加箔电极之间的新提出的电容耦合电极检测PD信号。在本文中,首先,应用了所提出的方法来使用通信电缆线检测PD,并且灵敏度被确定为100pc。其次,使用脉冲计数器制造简单的PD监测装置,并且性能令人满意。最后,已经尝试了解耦合电容器对检测强度的影响。此外,分析了不同安装条件下电力电缆的PD检测灵敏度。