This paper presents a CFD analysis on thermal comfort and energy consumption effected by partitions in an air-conditioned building. CFD experiments are carried out to simulate variables of indoor air before/after installation or removal of partitions. Accordingly, the Predicted Mean Vote (PMV) is determined as an indicator of thermal comfort while the cooling load of make-up air is calculated for energy consumption. Some simulated results are validated by measurements with good agreement where a case study is conducted in an air-conditioned space of a library. With the proposed methodology, it can be recommended in a case study that the significant effects of partition on thermal comfort are observed in the regions where occupants feel warmer and in the regions where occupants feel uncomfortably cool after installing the partition while the energy consumption increases by 24%. The installation of the partition at the desired location is not encouraged regarding to occupant's comfort and energy consumption without modification of the air-conditioning units.
机译:本文介绍了空调建筑中隔断的热舒适度和能量消耗的CFD分析。进行CFD实验,以在安装或移除隔板之前/之后模拟室内空气的变量。因此,预测的平均投票(PMV)被确定为热舒适指示器,同时计算化妆空气的冷却负荷以进行能量消耗。一些模拟结果通过测量验证,良好的一致性,其中在图书馆的空调空间中进行了案例研究。利用所提出的方法,可以推荐在一个情况下,在占用者感到温暖的地区观察到分区对热舒适性的显着影响,其中占用者在安装分区后占用者在能量消耗增加后感到不舒服的区域。 24%。在没有修改空调单元的情况下,不鼓励在所需位置处的分区安装分隔。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号