首页> 外文会议>International Conference on Alternative Energy in Developing Countries and Emerging Economies >The Study of Coefficient of Performance and Energy Efficiency of the 50 Tons Tube Ice Maker Machine by Finding the Optimal Diameter of a Heat Exchanger Machine for Installing In the Tube Ice Maker Machine
【24h】

The Study of Coefficient of Performance and Energy Efficiency of the 50 Tons Tube Ice Maker Machine by Finding the Optimal Diameter of a Heat Exchanger Machine for Installing In the Tube Ice Maker Machine

机译:50吨管制冰机的性能和能效系数研究通过找到换热器机械加工机械的热交换器机器的最佳直径

获取原文

摘要

This research is about finding the optimum heat exchanger diameter tube for consumable tubular ice production using Computational Fluid Dynamics (CFD) and apply in a 50 ton ice production facility to determine actual results. The analysis will compare six heat exchanger tube diameters from 0.5 to 3 inches using Computational Fluid Dynamics (CFD) in terms of heat transfer. It was found that the configuration using two inch is the optimum diameter for production. The results are compared to the benchmarked research made by Nakornsri et al. [1] it was able to save more energy by approximately 3.49 %. In terms of production capacity it is able to produce more than the previous referenced research by 3.24 %. The results are a guideline for energy saving to other ice factories.
机译:该研究是使用计算流体动力学(CFD)找到可消耗管冰的最佳热交换器直径管,并在50吨冰的生产设施中应用,以确定实际结果。在热传递方面,分析将使用计算流体动力学(CFD)比较六个热交换器管直径0.5至3英寸。发现使用两英寸的配置是生产的最佳直径。将结果与Nakornsri等人制作的基准研究进行了比较。 [1]它能够将更多的能量节省约3.49%。在生产能力方面,它能够以3.24%的3.24%生产超过先前的参考研究。结果是节能给其他冰工厂的指导。