首页> 外文会议>World Virtual Conference on Advanced Research in Mechanical and Materials Engineering >Numerical Analysis of Modified Ejector Cycle on Ejector as an Expansion Device on Residential Air Conditioner
【24h】

Numerical Analysis of Modified Ejector Cycle on Ejector as an Expansion Device on Residential Air Conditioner

机译:喷射器上变形式喷射器周期的数值分析作为住宅空调的膨胀装置

获取原文

摘要

The present study describes thermodynamic modeling of a novel cycle of ejector as an expansion device - called modified ejector cycle (MEC) - on residential air conditioner (A/C) to further enhance the COP improvement on standard ejector cycle (SEC). The difference between the SEC and MEC is the separator, namely the SEC uses a separator that has an inlet and two outlets, whereas in modified ejector cycle (MEC), the separator has only an inlet and an outlet in the system. Due to its environmental friendliness of R290 (propane), it is used to replace R22 as a working fluid in the numerical. The modeling results on the residential air conditioner with cooling capacity of 2.5 kW using R290 as working fluid showed that the COP improvement of the MEC was 42.86% at the condenser temperature of 45°C.
机译:本研究描述了作为膨胀装置的喷射器新循环的热力学建模 - 被称为改进的喷射器循环(MEC) - 在居住空调(A / C)上,以进一步增强标准喷射器循环(SEC)的COP改善。 SEC和MEC之间的差异是分离器,即SEC使用具有入口和两个出口的隔板,而在改进的喷射器循环(MEC)中,分离器仅在系统中仅具有入口和出口。由于其环境友好于R290(丙烷),它用于将R22替换为数值中的工作流体。使用R290作为工作流体的居住空调的居住空调的建模结果表明,在45℃的冷凝器温度下,MEC的CEC的COP改善为42.86%。