首页> 外文会议>International Mechanical Engineering Congress >A Numerical Investigation on the Performance of an Earth Air Heat Exchanger System for the Indian District of Nagpur
【24h】

A Numerical Investigation on the Performance of an Earth Air Heat Exchanger System for the Indian District of Nagpur

机译:Nagpur印度地区地球换热器系统性能的数值研究

获取原文

摘要

The performance of an Earth-Air Heat Exchanger (EAHE) system to be operated in climatic and soil conditions prevailing in the Indian district of Nagpur is modeled numerically. To do so, a CFD model is developed in ANSYS Fluent 12.1. The validation of the CFD model is carried out using data obtained from published literature and good agreement is established between the simulation results and published experimental data. An earth pipe of length 60 m and internal diameter 0.1 m is chosen for validating the model and this validated model is used to further investigate for three different lengths of the pipe - 40 m, 35 m and 30 m. The 3-dimensional flow field through the earth air heat exchanger is studied numerically by solving the appropriate governing equations namely: continuity, momentum and energy equations and a finite volume CFD code is employed for solving the same. An air inlet velocity of 2 m/s is maintained and the inlet temperature was varied between 308.1 K and 315 K for each chosen length. The decrease in temperature along the pipe length is plotted.
机译:在Nagpur印度地区普遍存在的气候和土壤条件下运作的地球 - 空气热交换器(EAHE)系统的性能在数值上进行了数字化。为此,CFD模型是在ANSYS FLUENT 12.1中开发的。使用从发布的文献中获得的数据进行CFD模型的验证,在仿真结果和公布的实验数据之间建立了良好的协议。选择长度60μm和内径0.1μm的地球管用于验证该模型,并且该验证的模型用于进一步研究三个不同长度的管道 - 40m,35 m和30米。通过求解适当的控制方程,通过求解适当的控制方程来使用地球空气热交换器进行三维流场,即:采用连续性,动量和能量方程,并且采用有限卷CFD码来解决该相同。保持2 m / s的空气入口速度,每个选择的长度在308.1k和315k之间变化入口温度。绘制沿管长度的温度降低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号