首页> 外文会议>Hydrovision International Conference and Exhibition >Turbine acceptance tests at Frieira HPP, Mino River, Spain with Acoustic Scintillation Flow Meter and Current Meters
【24h】

Turbine acceptance tests at Frieira HPP, Mino River, Spain with Acoustic Scintillation Flow Meter and Current Meters

机译:Frieira HPP,Mino River,西班牙的涡轮机验收测试,带有声学闪烁流量计和当前米

获取原文

摘要

In October 2007, Gas Natural Fenosa (formerly called Union Fenosa Generacion) successfully made flow measurements with the Acoustic Scintillation Flow Meter (ASFM) to establish the operational efficiency of existing turbines at their Velle, Frieira and Castrelo hydroelectric plants on the Mino River in north-western Spain. Subsequently, company personnel stipulated in their contract for replacement runners at these three plants that the ASFM would be used in the field acceptance tests in conjunction with flow measurements by the current meter method. The first of these tests took place on Unit 1 at the Frieira plant in June 2011. The Frieira plant has two Kaplan units, with nominal flow of 374 m3/s and the net head of 24.5 m. The results of the two methods were all within 1% and are discussed in the paper in detail, along with the procedures for the installation of the instruments and data collection.
机译:2007年10月,天然汽环(原来称为Union Fenosa Generacion)用声学闪烁流量计(ASFM)成功地进行了流量测量,以在北部的Mino河上的Mino河上建立现有涡轮机的运行效率 - 西班牙。 随后,在这三个工厂的替代跑步者的合同中规定了ASFM的合同,即在现场验收测试中使用当前仪表方法的流量测量。 这些测试中的第一个测试在2011年6月的Frieira植物中进行了第1单元。Frieira植物有两个Kaplan单位,标称流动为374 m3 / s,净头24.5米。 这两种方法的结果全部在1%以内,并详细讨论了本文,以及安装仪器和数据收集的程序。