首页> 外文会议>IEEE Far East Forum on Nondestructive Evaluation/Testing >Broken wires inspection for coated steel belts in elevator system using MFL method
【24h】

Broken wires inspection for coated steel belts in elevator system using MFL method

机译:使用MFL方法阻挡电梯系统中涂层钢带的断线检测

获取原文

摘要

Coated steel belts (CSBs) are becoming widely used in elevator systems due to their good performance. The reliability and safety of the belts are the most important factors for elevator operation. The difficulties for the belts testing are the small diameter of the rope and high lift-off distance during magnetic flux leakage (MFL) inspection, which will result in a fairly weak signal with low SNR. This paper presents hardware and software methods for overcoming the problems. By comparing two kinds of magnetic sensors, Hall and giant magneto-resistance (GMR) sensors, GMR sensors were used and differential sensing mechanism was designed to detect broken wires (BWs) from one side of the flat belt. Further, data processing method based on local variance was developed to enhance SNR. Novel equipment was developed and used for CSBs inspection in elevators. Experimental results show that the equipment could be applied to detect broken wires of coated steel belts successfully and has good sensitivity and reproducibility.
机译:由于其性能良好,涂层钢带(CSB)正在推进电梯系统。皮带的可靠性和安全性是电梯操作的最重要因素。皮带测试的困难是绳索的小直径和磁通量泄漏(MFL)检查期间的高升降距离,这将导致具有低SNR的相当弱的信号。本文介绍了克服问题的硬件和软件方法。通过比较两种磁传感器,霍尔和巨大的磁阻(GMR)传感器,使用GMR传感器,并且差动传感机构设计用于从平带的一侧检测断线(BWS)。此外,开发了基于局部方差的数据处理方法以增强SNR。开发了新颖的设备并用于电梯中的CSBS检查。实验结果表明,该设备可应用于成功地检测涂层钢带的断线,具有良好的敏感性和再现性。