首页> 外文会议>International Conference on Aerospace, Robotics, Manufacturing Systems, Mechanical Engineering, Neurorehabilitation and Human Motility >Analysis of Oxygen Transfer and Dissolved Oxygen Concentration Measurement Tests in a Wastewater Treatment Plant
【24h】

Analysis of Oxygen Transfer and Dissolved Oxygen Concentration Measurement Tests in a Wastewater Treatment Plant

机译:废水处理厂中氧转移及溶解氧浓度测量试验分析

获取原文

摘要

The efficiency of oxygen transfer depends on many factors including the type, size and shape of diffusers and the tank geometry. In this paper, the effect of the depth of water in the tank and the extension of coverage area of diffusers on each of oxygen transfer capacity, efficiency and dissolved oxygen concentration is tested. Experimental procedure is adopted to evaluate the effect of dissolved oxygen concentration. The results of the case study showed that, both the depth of water and the extent of coverage area of diffuser had a significant effect on the tested parameters. The values of oxygen transfer capacity was 76.7 kg O_2/h, oxygen efficiency (without agitation): 5.3 kg O_2/h and oxygen efficiency (with agitation): 4.2 kg O_2/h.
机译:氧气转移的效率取决于许多因素,包括漫射器和罐几何形状的类型,尺寸和形状。在本文中,测试了罐中的水深度和覆盖氧气浓度,效率和溶解氧浓度的扩散器的延伸区域的影响。采用实验程序来评估溶解氧浓度的效果。案例研究的结果表明,散热深度和扩散器的覆盖面积的程度对测试的参数具有显着影响。氧转移能力的值为76.7 kg O_2 / h,氧效率(无搅拌):5.3kg O_2 / h和氧效率(搅拌):4.2 kg O_2 / h。