"QiangGuang-I", working at short pulse state, can be used to research the transient radiation effects on electronic devices. The measurement of dose rate is significant for assessing devices' radiation-resistant ability. This paper comprehensively analyzes the originations of uncertainty on dose rate's measurement, such as thermoluminescent dosemeter's linearity degree and response to X-rays energy spectrum, testing instruments' resolution, waveforms' transmission distortion, and positional error; figures out the extended uncertainty. The result shows that the extended uncertainty of dose rate's measurement is less than 20%, which is satisfactory for researching on devices' transient radiation effects, and proves that the method used to measure dose rate is reasonable.
机译:在短脉冲状态下工作的“Qiangguang-i”可用于研究电子设备上的瞬态辐射效应。剂量率的测量对于评估装置的抗辐射能力是显着的。本文全面分析了剂量率测量的不确定性的起源,如热敏发光剂量计的线性度程度和对X射线能谱的响应,测试仪器分辨率,波形的传输失真和位置误差;数字出局了延长的不确定性。结果表明,剂量率测量的延长不确定度小于20%,对于研究设备的瞬态辐射效应是令人满意的,并证明用于测量剂量率的方法是合理的。