摘要

In this paper, metallographic examination, visual examination and scanning electron microscopy were used to analyze the perforation failure of the differential pressure transmitter impulse pipe. Macrostructure and microstructure of the hole, corrosion characteristics, and corrosion products were studied. Combined with the service conditions of natural gas pipe, relationship between the pipe material quality and the formation process of the perforation failure was determined utilizing fracture mechanics and corrosion analysis. The perforation failure may be caused by the defects and stress corrosion.
机译:本文采用了金相检查,视觉检查和扫描电子显微镜来分析差压变送器脉冲管的穿孔失效。研究了孔,腐蚀特性和腐蚀产品的宏观结构和微观结构。结合天然气管的服务条件,利用断裂力学和腐蚀分析确定管材质量与穿孔失效的形成过程之间的关系。穿孔失效可能是由缺陷和应力腐蚀引起的。