首页> 外文会议>International Conference on Renewable Energy and Environmental Technology >Study of Cold-State Aerodynamic Field Test on the Outlet of 2150 t/h Supercritical Once-through Boiler
【24h】

Study of Cold-State Aerodynamic Field Test on the Outlet of 2150 t/h Supercritical Once-through Boiler

机译:2150 T / H超临界一体式锅炉出口的冷凝电气空气动力场试验研究

获取原文

摘要

The new unit putting into production is the supercritical boiler with a level of or above 600 MW, and most of them take the corner tangential combustion technology. The Long-term operation practice shows that there is gas temperature deviation on all the horizontal flues of boilers, which usually leads to the overheating tube burst of the high-temperature superheater and reheater, thus threats the safe and economic operation of power station. Towards the gas temperature deviation phenomenon that exists commonly in tangentially fired boiler, this paper went on the pertinent cold-state aerodynamic field test on the tangentially fired boilers in one new power plant and studied the airflow velocity at the furnace outlet in eight vertical levels by changing the SOFA horizontally rotating angle. The experiment showed that changing the baffle's opening and horizontally rotating angle of SOFA air door could adjust airflow quite well and make it uniform, furthermore, the airflow can reach a basic balance at the biggest anti-tangential angle. This paper has some reference value towards improving the gas temperature deviation problem of tangentially fired boilers.
机译:投入生产的新单位是超临界锅炉,水平或高于600兆瓦,其中大部分采用拐角切线燃烧技术。长期操作实践表明,锅炉的所有水平燃道上存在气体温度偏差,这通常导致高温过热器和再热器的过热管爆发,从而威胁到电站的安全和经济运行。朝向在切向燃烧锅炉中通常存在的气体温度偏差现象,本文在一个新的电厂中的切向燃烧锅炉上采用了相关的冷凝固性锅炉,并在八个垂直水平中研究了炉出口的气流速度改变沙发水平旋转角度。该实验表明,改变挡板的开口和水平旋转角度的沙发空气门可以很好地调节气流并使其均匀,此外,气流可以以最大的抗切线角度达到基本平衡。本文对改善切向燃烧锅炉的气体温度偏差问题有一些参考值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号